Journal of Diagnostic Medical Sonography

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for free access to the SAGE eReference platform!

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Scott, T.
Right arrow Articles by Voss, M.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Diagnostic Medical Sonography, Vol. 20, No. 5, 326-334 (2004)
DOI: 10.1177/8756479304267641

Sonographic Detection of the Normal Appendix

Does the Combination of Real-Time Spatial Compounding and Tissue Harmonic Imaging Make a Difference?

Ted Scott, MAPPSC, RDMS, RVT, RDCS

Institute for Applied Health Sciences, Mohawk College, Hamilton, Ontario, Canada, ted.scott{at}mohawkcollege.ca

Hans Swan, PhD

School of Clinical Sciences, Charles Sturt University, Wagga Wagga, Australia

Eric Jurriaans, MD, FRCP

St. Joseph’s Healthcare, Hamilton, Ontario, Canada

M. Voss, MD, FRCP

St. Joseph’s Healthcare, Hamilton, Ontario, Canada

The purpose of this study was to determine if the application of tissue harmonic imaging (THI) and real-time spatial compounding (RTSC) would result in a significant difference in the rate of detection and quality of visualization of the normal appendix. Subjects were scanned using the experimental method (the combination of THI and RTSC) and the conventional method (without THI and RTSC). The rate of detection was 85% with the experimental method and 66% with the conventional method. The quality of visualization was measured across three scales—visualized length, walls, and lumen—with a total score equal to the sum of the three scales. The experimental method demonstrated a significant difference in visualized length and total score. The mean score for length using the conventional method was 2.18 compared with 2.56 for the experimental method. The mean score for all three scales for the conventional method was 7.97 compared with 8.67 for the experimental method.

Key Words: sonography • appendix • image quality • detection • real-time spatial compounding • tissue harmonic


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?